I. EXAMINATION:
- Check the engine oil (with oil under the oil must always be at the maximum) if there is not enough without the right supplements and avoid shortages viscosity leads to the coast.
- To check the coolant (in water tanks, water must be topped up) if there is not enough, without additional dump to avoid water shortages lead to overheat, piston bunch, blowing zoang quylat.
- To check the belts have not coincided, if identical to rise.
- Check the batteries to see if tight Squeeze, if liquid to be tightened, avoid battery explosion Move, tuck burning machine.
- Check the battery acid water if there is not enough, without additional pour.
- Check the output load requirements whether liquid, if liquid to be tightened, to avoid short-circuiting the Move resulting liquid, burning machine.
II. START THE ENGINE:
2.1 Explosion machine manually:
- Switch the mode switch to OFF
- Turn the key clockwise under 10 seconds, the ignition release his hand.
- When the ignition must be regularly checked around the machine to see if the oil leak, where the water is not, if it leaks must be immediately remedied. Where not fix the company to report Truong Loc (0913.340.660).
- Check to see if the water temperature at a safe level zero (70-90 degrees)
- Check the machine to see if different bangs, if so must overcome.
- Check the oil pressure at a safe level can not (from 2.5kg to safe levels 6kg)
- Check if there is enough voltage (from 380V to 400V), check whether there is enough frequency (50Hz to 52Hz from)
- If the pressure, voltage, frequency is not enough to rectify.
- Check to see if battery charging is not loaded, check the voltage of each phase in 3-phase switching 3 modes, checking line of each phase load weight by switching switches A.
- Close the load generator is transferred to the GEN switch, shut off power load is transferred to the MAIN switch.
2.2 Burst mode with automatic machine:
- Switch the toggle switch to the AUTO mode, the key is always subject to the OFF position.
- When a power loss, phase loss ... it will automatically explode and vice versa.
- If all the specifications have ensured safety norms mode then shut the load Circuit Breakers.
Attention:
- Request to close large loads to shut down the load pickup.
- Absolutely not idling overload fracture leads to the crankshaft, piston bunch heater ...
- When the machine has worked to regularly walk around the machine checking the technical condition of the machine, check the oil pressure, water temperature and clock V, Hz, A.
III. SHUTDOWN:
- Cut out the load, Cut Circuit Breakers, shutdown (turn the key counterclockwise until the computer clock is stopped releasing his hand).
Attention:
- Must industrial hygiene before and after each shift machine.
- Be prepared equipment fire prevention, precaution incident.
- It is recommended that those without duties arbitrarily adjust the machine's specifications.
- After 200 hours running to change the oil, filter cup, running fuel (diesel)
- Lubrication: Oil HD50